Torsionally Flexible Couplings
 
   
 

Service factors have evolved from experience & are based on past failures. Values listed in this brochure are intended only as a general guide, and are typical of usual service requirements. For systems which frequently utilise the peak torque capacity of the power source, verify that the magnitude of this peak torque does not exceed the 1.0 service factor rating of the coupling selected. Applications which involve extreme repetitive shock or high energy load absorption characteristics should be referred, with full particulars to NENCO.

 
   
 
Aerator 2.0 Freight & Passenger 2.0 Suction Rolls 2.0
Agitators     Feeders     Suction Presses 2.0
Vertical & Horizontal     Apron, Belt, Screw 1.0 Conveyors 1.2
Screw, propeller, Paddle 1.0 Reciprocating 2.5 Plastic Industry Machines    
Barge Haul Pullers 2.0 Generators     Extruders 1.5
Beaters 1.5 Even Load 1.0 Crushers 1.5
Blowers, Ventilators     Welding 2.0 Calenders 1.5
Centrifugal 1.0 Hoist or Railway Service 1.5 Mixers 1.5
Lobe or Vane 1.25 Hammer Mills 2.0 Printing Presses 1.5
Cooling tower fans 2.0 Kilns 1.5 Pumps    
Induced Draught fans 1.25 Laundry Washer or Tumbler 2.0 Centrifugal 1.0
Rotary Piston Blowers 1.25 Line Shafts & Processing Machinery 1.5 - Light Liquids 1.25
Turbo Blowers 1.0 Lumber Machinery     - Semi Liquids 1.25
Propellor Fans 1.5 Band Resaw 2.0 - Constant Speed 1.0
Building Machinery     Planer 2.0 - Frequent Speed Changes under load 1.25
Concrete Mixers 1.25 Slab Conveyor 2.0 Gear, Rotary or vane 1.25
Hoists 1.25 Log Haul 2.0 Reciprocating    
Road Construction Machinery 1.25 Machine Tools     - 1 Cyl. Single or Double Acting 3.0
Can Filling Machinery 1.0 Main Drive 1.5 - 2 Cyl. Single Acting 2.0
Car Handling Machinery     Bending Roll 2.0 - 2 Cyl. Double Acting 1.75
Car Dumpers 2.5 Aux. & Traverse Drive 1.0 - 3 or more cylinders 1.5
Car Pullers 1.5 Punch Press, Plate Planer 2.0 Piston Pumps 2.0
Compressors     Metal Rolling Mills     Plunger Pumps 2.0
Centrifugal 1.0 Billet Shears 2.0 Pressure Pumps 2.0
Lobe or Vane 1.25 Cold Rolling Mills 1.5 Rubber Machinery    
Rotary, Screw 1.0 Drawbench 2.0 Calenders 2.0
Reciprocating * Cooling beds 1.5 Extruders 1.75
Conveyors     Feed Rolls-Blooming Mill 3.0 Banbury Mixer 2.5
Apron 1.0 Roller Tables (Light) 2.0 Tyre Building Machine 2.5
Assembly 1.0 Roller Tables (Heavy) 3.0 Sugar Industry    
Belt 1.0 Hot & Cold Saws 2.0 Cane carrier & leveller 1.75
Chain 1.0 Piercer 3.0 Cane Knife & crusher 2.0
Screw 1.0 Metal Forming Machines     Mill Stands, Turbine driven with all    
Bucket 1.25 Draw Bench Carriage 2.0 Helical or Herringbone Gears 1.5
Live Roll, Shaker, Reciprocating 3.0 Extruder 2.0 Stone & Clay working machines    
Link 1.25 Forming Machine 2.0 Ball Mills 2.0
Passenger Lifts 1.25 Sitters 1.0 Beater Mills 2.0
Goods Lift 1.25 Wire Drawing / Flattening 1.5 Hammer Mills 2.0
Shaker 3.0 Wire Winder 1.5 Brick Presses 2.0
Oven 1.2 Coilers & Uncoilers 1.5 Screens    
Cranes & Hoists     Table Conveyors 2.5 Air Washing 1.0
Main Hoists 2.0 Mills (Rotary)     Rotary Coal or Sand 1.5
Skip Hoists 2.0 Ball 2.0 Vibrating 2.5
Bridge, Travel or Trolley 2.0 Cement Kilns 2.0 Water 1.0
Slope 2.0 Dryers, Coolers 2.0 Steering Gear 1.0
Reversing 2.0 Rolling 2.0 Stockers 1.0
Crushers     Tumbling 1.5 Textile Machines    
Ore 3.0 Pebble 2.0 Batchers 1.25
Stone 3.0 Tube 2.0 Looms 1.25
Dredgers     Mixers     Cloth Finishing Machine 1.5
Cable Reels 2.0 Concrete 1.75 Printing & Dyeing Machines 1.25
Conveyors 1.5 Muller 1.5 Willows 1.25
Cutter Head, Jig Drive 2.5 Paper Machines     Spinner, Tenter Frame, Winder 1.5
Pumps 1.5 Calenders 1.5 Tumbling Barrel 1.75
Dynamometer 1.0 Barker Auxillary 2.0 Woodworking Machinery 1.0
Elevators     Couches 2.0 Windlass 2.0
Bucket 1.5 Drying / Glazing Cylinders 2.0 Water Treatment    
Escalators 1.0 Pulpers 1.5 Aerators 1.5
Gravity Discharge 1.5 Dryers 1.5 Screw Pumps 1.5
 
 
* Consult NENCO
 
   
 

Note: Values contained in the table are to be applied to smooth power sources such as electric motors, steam turbines, and internal combustion engines of four or more cylinders. For drives involving internal combustion engines of two cylinders, add 0.3, and for a single cylinder, add 0.7 to the values listed. Service factors become less significant when the load & duty cycles are known. It is only when a system is not analysed in depth that service factors must be used.

The specifications provided are based on several years of research in the field of flexible couplings. Under field conditions, however, unknown parameters and conditions may restrict the value of the aforesaid calculations, so that practical tests by the user are necessary. Because of the numerous applications of our products, we cannnot guarantee that our recommendations are correct in every case.

 
     
   
     
Copyright © 2008 by National Engineering Company. All Rights Reserved.